-
-
Cardiology
-
Clinical Oncology
-
Dental
-
Dermatology
-
Ear, Nose, Throat (ENT)
-
Endocrinology
-
Gastroenterology
-
General Surgery
-
Gynecology & Obstetrics
-
Interventional Cardiology
-
Nephrology
-
Neurology
-
Oncology Surgery
-
Ophthalmology
-
Orthopedics
-
Pediatrics
-
Pediatrics Surgery
-
Physiotherapy
-
Plastic Surgery
-
Psychiatry & Psychology
-
Radiology
-
Urology
-
Vascular Surgery
-
Iron(II) Sulfide Fused Sticks are solid forms of ferrous sulfide, an inorganic metal sulfide supplied for controlled laboratory reactions. When treated with suitable dilute acids, iron(II) sulfide can release hydrogen sulfide gas (H2S), which is highly toxic and can rapidly cause serious harm at elevated concentrations. This reaction is used in specific laboratory procedures for generating small quantities of hydrogen sulfide where approved apparatus and effective containment are available. The sticks are not suitable for casual demonstrations or open-bench gas generation. Use only under an approved risk assessment, appropriate engineering controls, and trained supervision, following the product SDS and institutional procedures.
Product Specifications
| Specification | Details |
|---|---|
| Appearance | Dark brown to black fused sticks |
| Assay | 99% |
| Chemical Name | Iron(II) sulfide |
| Alternate Names | Ferrous sulfide; iron monosulfide |
| Molecular Formula | FeS |
| Empirical Formula | FeS |
| CAS Number | 1317-37-9 |
| Molecular Weight | 87.91 g/mol |
| Grade | LR Laboratory Reagent |
Key Features of Iron Sulphide Sticks Fused Sticks For Producing H2S
- Inorganic iron(II) sulfide with formula FeS.
- CAS number 1317-37-9 and formula mass approximately 87.91 g/mol.
- Supplied as fused solid sticks for specified laboratory gas-generation procedures.
- Reacts with suitable dilute acids to release hydrogen sulfide gas.
- Hydrogen sulfide is acutely toxic; use requires strict engineering and procedural controls.
Laboratory Applications of Iron Sulphide Sticks Fused Sticks For Producing H2S
- Controlled laboratory preparation of hydrogen sulfide only where authorised by an approved procedure.
- Demonstration of metal sulfide reactions in a suitably equipped laboratory under expert supervision.
- Inorganic chemistry studies of sulfide compounds and acid reactions using appropriate containment.
- Research procedures requiring a defined source of hydrogen sulfide under validated gas-handling controls.
- Laboratory training on chemical risk assessment and gas-generation hazards without uncontrolled release.
Why Choose Lab Wale to Buy Iron Sulphide Sticks Fused Sticks For Producing H2S
Lab Wale provides a convenient sourcing option for laboratory chemicals and scientific supplies used by schools, colleges, universities, research centres, and laboratory professionals. Before purchasing Iron Sulphide Sticks Fused Sticks For Producing H2S, check the chemical identity, intended application, stated grade, and available technical or safety information to ensure the material suits the procedure. Selecting the correct form and following the relevant laboratory method are important for appropriate use.
Frequently Asked Questions About Iron Sulphide Sticks Fused Sticks For Producing H2S
What are fused iron(II) sulfide sticks used for?
They are used in certain controlled laboratory procedures to generate hydrogen sulfide by reacting iron(II) sulfide with a suitable dilute acid. Because hydrogen sulfide is highly toxic, the reaction requires approved containment and trained supervision.
What is the formula of iron(II) sulfide?
Iron(II) sulfide has the formula FeS and a formula mass of approximately 87.91 g/mol. Its commonly listed CAS Registry Number is 1317-37-9.
Why is hydrogen sulfide generation hazardous?
Hydrogen sulfide is acutely toxic and can cause severe effects at dangerous concentrations. Odour is not a reliable warning, so generation must never be carried out in an uncontrolled or poorly ventilated area.
Can these sticks be used for an ordinary classroom demonstration?
Only if the institution has an approved procedure, suitable engineering controls, trained supervision, and appropriate gas-handling equipment. Open-bench or uncontrolled hydrogen sulfide generation is inappropriate.
How should iron(II) sulfide sticks be stored and handled?
Keep them in a tightly closed, labelled container in a dry place and segregate them from acids and incompatible materials. Avoid dust and breakage, use suitable PPE, and follow the SDS and institutional procedures for hazardous gas-generating reagents.
Storage Conditions for Iron Sulphide Sticks Fused Sticks For Producing H2S
Store in a tightly closed, labelled container in a dry, cool place, segregated from acids and incompatible materials. Protect the sticks from breakage and contamination. Follow the product SDS and institutional rules for reagents capable of releasing toxic gas.
Precautions for Handling Iron Sulphide Sticks Fused Sticks For Producing H2S
Use only under an approved risk assessment and trained supervision with suitable engineering controls for hydrogen sulfide. Never generate H2S in an open or uncontrolled area. Wear suitable PPE, avoid dust and breakage, keep the material away from acids until use, and follow the institution’s gas-monitoring, emergency, and waste procedures.


Anatomy Lab Equipments
Biochemistry Lab Equipments
Biology Lab Equipments
Chemistry Lab Equipments
Cytology Lab Equipments
Cytopathology Lab Equipments
Dental Lab Equipments
Forensic Lab Equipments
Genetics Lab Equipments
Hematology Lab Equipments
Histology Lab Equipments
Histopathology Lab Equipments
Mathematics Lab Equipments
Microbiology Lab Equipments
Molecular Biology Lab Equipments
Pathology Lab Equipments
Pharmaceutical Lab Equipments
Physics Lab Equipments
Radiology Lab Equipments
Science Lab Kit’s
Toxicology Lab Equipments

Borosilicate Glass Beaker
Plastic Beaker (Euro Design)
Plastic Beaker (Printed Graduation)
Test Tube Brush
Measuring Cylinder Brush
Conical Flask Brush
Volumetric Flask Brush
Round Bottom Flask Brush
Glass Beaker Brush
Pipette Brush
Wash Bottle Brush
Borosilicate Büchner Flask
Borosilicate Erlenmeyer/Conical Flask
Borosilicate Pear-Shaped Flask
Borosilicate Round Bottom Flask
Plastic Conical Flask
Plastic Volumetric Flask
Bunsen Burner
Spirit Lamp
Borosilicate Glass Burette
Plastic Burette
Capillary Tube
Centrifuge Tube
Test Tube
Ria Vial
Vacutainer Tubes
Syringes
Student Microscope
Binocular Microscope
Dissecting Microscope
Microscope Glass Slides
Cover Slip
Inoculating Loop
Slide Box
Lamps
Oils
Beaker Tongs
Crucible Tongs
Flask Tongs
Borosilicate Glass Funnel
Plastic Funnels
Wash Bottle
Borosilicate Glass Reagent Bottle
Plastic Reagent Bottle
Borosilicate Measuring Cylinder
Plastic Measuring Cylinder
Borosilicate Glass Graduated Pipette
Borosilicate Glass Volumetric Pipette
HB Pipette
Pasteur Pipette
Micropipettes
Micropipette Tips
Filter Paper
Litmus Paper
pH Paper
Chromatography Paper
Plastic Petri Plates (Sterile)
Glass Petri Plates (Non-Sterile)
Safety Goggles
Lab Coats
Gloves
Masks
Shoe Covers
Hair & Beard Covers
Steel Spatula
Plastic Spatula
Hitachi Sample Cup
Plastic Scoop
Plastic Medicine Cup
Dissecting Tool Kit
Dissecting Forceps
Hemostatic Forceps
Blood Culture Bottle
Urine Container
Wooden Swab Stick
Test Tube Holder
Test Tube Racks
Magnifying Glass
Watch Glass
Mortar and Pestle
Coplin Jar
Plastic Stirrer
Glass Stirrer
Crucible
Tripod
Wire Mesh
Laboratory Thermometer
Tourniquet
Alcohol Swab
Blood Lancet
Bandage
Gloves & Masks











Cardiology
Clinical Oncology







Reviews
Clear filtersThere are no reviews yet.